What are the controls and what do they do?

If you look around your hot water cylinder, you will probably see several valves, pipes and electrical controls. You might also see a smaller vessel nearby and a funnel-shaped fitting in the pipework.

Each has a job to do. Some control everyday operation, while others provide protection if something goes wrong.

This guide explains the main components on an unvented hot water cylinder, Hot water cylinderswhat they do and how you might recognise them. Designs vary, so the descriptions below are a guide rather than a way to identify a replacement part.

Important safety warning

An unvented hot water cylinder stores water under mains pressure and may contain water hot enough to cause serious scalding. Its safety controls, electrical connections, valves and discharge pipework must be inspected, tested, adjusted or repaired only by a suitably qualified professional.

Do not remove covers, operate valves, reset safety cut-outs, adjust controls or disconnect pipework yourself.

If you see steam, very hot water, a forceful discharge, a major leak, signs of overheating or rapidly worsening conditions, keep well clear of the cylinder, valves and discharge pipework. Do not touch the system. Seek urgent professional help.

Never block, cap or obstruct a tundish or discharge pipe. It may be carrying hot water away from a safety valve.

1. The thermostat: controlling everyday temperature

The thermostat controls how hot the stored water gets. When the water reaches the set temperature, it tells the system to stop heating it. As the water cools, it allows heating again when the hot-water programme calls for it.

What does it look like?
On many cylinders, it sits behind a plastic cover on the side of the cylinder. An immersion heater has its own temperature control, usually beneath its electrical cover. You may see a temperature dial, but some controls are concealed.

Do not remove the cover or attempt to test, adjust or replace the thermostat. Electrical testing and fault diagnosis require appropriate training and equipment.

 

2. The high-limit cut-out: backup protection against overheating

The high-limit cut-out provides a separate layer of protection if normal temperature control fails.

If the water becomes too hot, it interrupts the heating. Depending on the system, it cuts power to the immersion heater or works through the controls that stop heat reaching the cylinder.

A cut-out that has operated needs professional investigation. Do not reset it yourself or repeatedly restore the heating, as this may leave an underlying fault unresolved and could create a serious safety risk.

What does it look like?
It is often built into the same assembly as the thermostat, so there may be no separate visible component. Its reset button is usually behind a cover.

Do not remove any covers or touch the reset button. This could expose you to live electrical parts, hot water or stored pressure.

 

3. The motorised valve: stopping heat entering the cylinder

On many indirectly heated cylinders, a two-port motorised valve controls the flow of heating water through the cylinder’s internal coil.

When correctly installed and wired, it works with the thermostat and high-limit cut-out to stop that flow when required. This gives the controls a physical way to stop more heat entering the cylinder.

What does it look like?
Usually a brass valve in the heating pipework with a small rectangular metal or plastic box on top and an electrical cable coming from it.

This arrangement applies to relevant indirectly heated systems; an electrically heated cylinder may not have one.

Do not manually operate, disconnect, remove or replace the valve. Its correct operation depends on the system controls and wiring.

 

4. The pressure-reducing valve: controlling incoming pressure

Mains water pressure can be higher than the cylinder is designed to operate at. The pressure-reducing valve brings incoming pressure down to the level specified for the system.

It is often part of an inlet control group, which may also contain a strainer, a check valve and an expansion relief valve.

The strainer catches debris. The check valve helps prevent water flowing backwards towards the supply.

What does it look like?
Usually a brass fitting or group of fittings on the cold-water supply to the cylinder, often with a plastic cap or cartridge housing. Several functions may be combined in one assembly.

Do not adjust the pressure-reducing valve or attempt to clean, remove or replace any part of the inlet control group. Incorrect adjustment can affect the cylinder’s operating pressure and safety.

 

5. The expansion vessel: allowing room for heated water

Water expands as it heats up. In an unvented system, that extra volume needs somewhere to go.

An expansion vessel contains a flexible membrane separating water from a cushion of air or gas. This cushion compresses as the water expands, helping manage the pressure increase.

Some cylinders use an internal air space instead, so the absence of an external vessel does not automatically mean something is missing.

What does it look like?
A smaller round or oval metal vessel, commonly white on domestic hot-water systems, connected to the cylinder’s pipework. Colour alone does not identify its purpose: a nearby vessel may serve the heating system instead.

Expansion vessels require specialist checks and may need pressure testing or recharging. Do not disconnect, recharge, puncture or replace one yourself.

 

6. The expansion relief valve: releasing excess pressure

If pressure rises above this valve’s set limit, it opens to release water into the discharge pipework.

It is a protective component, rather than the normal way the system should accommodate expanding water. Regular discharge can point to an expansion or pressure-control problem, although the valve itself may also need attention.

What does it look like?
Typically a small brass valve with a plastic operating cap and a discharge connection. It is often fitted within or close to the inlet control group.

Do not operate the valve, hold it open, remove its cap or attempt to stop it dripping. A discharge indicates that the system needs professional assessment.

 

7. The temperature and pressure relief valve: protection against either condition

Often called the T&P valve, this valve opens if the water temperature or pressure reaches its specified safety limit.

It provides another layer of protection alongside the temperature controls and other pressure-management components.

What does it look like?
Usually a brass valve fitted directly into the cylinder, often towards the top, with a test cap or lever and a pipe leading towards the discharge arrangement. It may be partly covered by insulation.

Some cylinder designs combine relief functions differently, so the manufacturer’s information matters.

Do not operate or test the T&P valve yourself. Do not obstruct its discharge route. If it has discharged, arrange an urgent inspection by a suitably qualified professional.

 

8. The tundish and discharge pipework: making discharge visible and carrying it away

The tundish is the fitting with a visible air gap in the discharge route. It allows you to see when water is passing from a relief valve.

The pipework below it carries that water to a suitable discharge point. Both the route and its installation matter because discharged water can be very hot.

What does it look like?
Often a small black funnel-shaped fitting with an opening or viewing section between the pipe above and the pipe below.

The tundish does not cause the pressure problem. If it is dripping, it is showing you that something upstream needs checking.

Do not touch, block, cap, tape or alter the tundish or discharge pipework. A continuous, forceful or hot discharge requires urgent professional attention.

 

What should you do if something does not look right?

Do not attempt to investigate the components yourself. Do not remove covers, reset a high-limit cut-out, adjust pressure-reducing valves, operate relief valves, recharge an expansion vessel, disconnect pipework or replace any component.

A qualified professional should carry out electrical testing, pressure checks, discharge-route inspections and all work on safety components.

Without touching the system, you may be able to report:

  • Visible dripping, leaking, corrosion or staining around the cylinder, valves, tundish or discharge pipework.
  • Water or steam coming from the tundish or discharge pipe.
  • Changes in hot-water temperature, unusual noises, loss of hot water or repeated operation of a warning light or control.
  • When the problem occurs, such as during or after the cylinder heats.
  • Clear photographs taken from outside covers and away from hot or discharging pipework.

These observations can help a qualified professional diagnose the fault. They do not confirm which component has failed.

Arrange prompt professional attention for persistent dripping, leaks, unusual temperatures, loss of hot water or repeated cut-out operation.

Seek urgent help if there is steam, very hot water, a forceful discharge, a major leak, rapidly worsening leakage or any sign of overheating. Keep clear of the cylinder and discharge pipework. Do not touch the system. If it is safe to do so, use only the normal external controls to switch off the cylinder’s heat sources, without removing covers or approaching hot or discharging components. If you cannot do this safely, leave the system alone and contact an emergency plumber.

At GPJ Plumbing, I check how these components work together and explain what I find in plain English. A dripping valve does not automatically mean you need a new cylinder—or even that the valve itself is the cause. The useful first step is finding out why it is happening.

Gez — GPJ Plumbing, G3-qualified for unvented hot-water systems.